3M Smoke and Sound Sausage Sealant 20oz.Our 3Mā¢ Smoke and Sound Sealant SS100 is designed to seal
construction joints and through penetrations in non-fire-rated wall and
floor assemblies. In addition, this latex sealant acts as a draftstop to
prevent unwanted air movement while providing a barrier against dust
and other airborne particulates. Features: - Creates an effective barrier to mitigate smoke and toxic gas spread
- Helps minimize sound transfer
- Latex acts as a draftstop to prevent unwanted air movement
- Sealant provides a barrier against dust and other airborne particulates
- Adheres to a full range of construction substrates
- Elastomeric polymer stretches and constricts depending on volume
FIRE CAULK
Technical Service 1-800-992-1180 STI Product Data Sheet ā¢ Series SNS Acoustical Sealant ā¢ FOD-5104 2006 1 www.stifirestop.com ā¢ Economical High performance without the high price! ā¢ Safe Safe for contact with plastics. ā¢ Water Resistant Will not re-emulsify when dry. ā¢ Water-Based Easy installation, cleanup, and disposal. ā¢ Remains Flexible Allows movement. ā¢ Acoustically Tested Reduces noise transmission. ā¢ Low VOCs Safe, No solvents, Non-Halogenated ā¢ Paintable SMOKE āNā SOUND ACOUSTICAL SEALANT APPLICATIONS PRODUCT DESCRIPTION SpecSealĀ® Smoke āNā Sound Sealant has superb color stability and resistance to ultraviolet rays, ozone, and airborne contaminants. It is also mildew resistant and meets Class A finish requirements for Flame Spread and Smoke Development when tested in accordance with ASTM E84. SpecSealĀ® Smoke āNā Sound Sealant provides less than one cfm air leakage when tested in accordance with UL1479 and UL2079 and is also acoustically tested and classified, demonstrating excellent sound attenuation properties. PERFORMANCE PHYSICAL PROPERTIES Product Name: Smoke 'N' Sound Sealant Leakage: ā¤1 CFM per UL1479 Color : White or Safety Yellow Odor: Mild Latex Specific Gravity: 1.56 Solids Content by Weight: 83% Solids Content by Volume: 71% pH: 7.0 ā 7.5 VOC: 20 g/L (.17 lb./gal) (ASTM D3960 OR EPA Method 24) FEATURE BENEFIT PRODUCT DATA SHEET SpecSealĀ® Smoke āNā Sound Sealant is a high quality acrylic latex sealant designed for sealing through-penetrations (such as pipes, conduits, cabling, busways, openings), membrane penetrations (such as p-traps and outlet boxes) in smoke rated walls. SpecSeal Smoke āNā Sound may also be used in linear applications such as wall-to-wall and head-of-wall joints where joints are designed to be either static or minimally dynamic. SpecSealĀ® Smoke āNā Sound Sealant is available in a single grade that has excellent caulking properties as well as high build properties on vertical or overhead surfaces. This single grade may be caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeal Smoke āNā Sound contains no PCBās nor asbestos. SpecSealĀ® Smoke āNā Sound Sealant is storage stable (when stored according to the manufacturerās recommendations), is asbestos free and will not separate nor excessively shrink when dried. Smoke āNā Sound will adhere to all common construction and penetrant materials and contains no solvents that might adversely affect plastic pipes or cable jackets. SMOKE CONTROL: Where stopping the passage of smoke is necessary such as in smoke barrier walls. NOISE CONTROL: Where reducing the transmission of sound through wall openings is necessary to help ensure occupant privacy and peaceful environment. INFECTIOUS/DUST CONTROL: Where reducing the transmission of dust and other airborne particulates through wall openings is necessary. ASTM C834: Complies ASTM D217: 260 77Ā°F In-Service Temp.: Less than 185Ā°F (85Ā°C) Storage Temp.: 40Ā°F (4Ā°C) - 95Ā°F (35Ā°C) Flame Spread: 5 Smoke Development: 0 STC Rating: 62 (Relates to specific construction) (ASTM E 90-04/ASTM C919) Shelf Life: 2 Years PROPERTIES (cont.) SMOKE 'N' SOUND SEALANT SPECIFICATIONS The smoke sealing caulk shall be a water based, high quality latex sealant and shall dry to a water resistant and flexible smoke barrier when dry. The sealant shall be tested for smoke sealing, noise abatement (acoustical) properties and shall meet Class A finish requirements when tested in accordance with ASTM E84 (UL723). SPECIFIED DIVISIONS DIV. 7 ā 07 90 00 ā Joint Protection DIV. 9 ā 09 20 00 ā Plaster and Gypsum Board DIV. 22 ā 09 20 00 ā Plumbing DIV. 26 ā 26 00 00 ā Electrical PROPERTIES SMOKE 'N' SOUND SEALANT 2 STI Product Data Sheet ā¢ Series SNS Acoustical Sealant ā¢ FOD-5104 2006 Technical Service 1-800-992-1180 www.stifirestop.com INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation temperatures must be between 35Ā° F (2Ā°C) and 100ĖF (38Ā°C). Allow product to dry a minimum of 24 hours before exposure to moisture. SpecSealĀ® Smoke āNā Sound may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun, or by manually troweling using a masonās trowel or putty knife. If the sealant tends to pull back from a surface, clean the surface with a damp rag or sponge and reapply. Work sealant into all areas exercising care to eliminate voids or seams. Adding water to the sealant is not recommended. 1/2" Depth BOTH Sides of Wall Full Depth ONE Side of Wall Concrete Floor SpecSealĀ® Smoke 'N Sound Sealant Fiberglass Batt Insulation or Mineral Wool Batt Insulation Gypsum Wall 1/4" Depth BOTH Sides of Wall 1/4" Bead Gypsum Tight to Floor or at Track SpecSealĀ® Smoke 'N Sound Sealant Through Penetration Gypsum Wall SpecSealĀ® Smoke 'N Sound Sealant Concrete Floor Concrete Floor Gypsum Wall Gypsum Wall SpecSealĀ® Smoke 'N Sound Sealant Concrete Floor Concrete Floor Gypsum Wall Gypsum Wall SpecSealĀ® Smoke 'N' Sound Sealant Mineral Wool Batt Insulation or Fiberglass Batt Insulation Concrete Floor SpecSealĀ® Smoke 'N Sound Sealant Gypsum Wall Technical Service 1-800-992-1180 STI Product Data Sheet ā¢ Series SNS Acoustical Sealant ā¢ FOD-5104 2006 3 www.stifirestop.com SEALING JOINTS & LINEAR GAPS: The width of the joint should be approximately 12 times the anticipated movement and should fall within the range of 1/4ā (6 mm) to 3/4ā (19 mm). The depth of the joint should be 1/4ā (6 mm) minimum to 3/8ā (9 mm) maximum. JOINT BACKING: Joints greater than 3/8ā (9 mm) deep should be filled to within 3/8ā (9 mm) of the surface with either polyethylene or polyurethane backer rod, preferably of a non-gassing, non-absorbing type. Use a diameter that will compress about 25% when installed. In joints too shallow to take backer rod, use a bond breaker tape to prevent three-sided adhesion. INSTALLATION INSTRUCTIONS - (CONTINUED) 4 STI Product Data Sheet ā¢ Series SNS Acoustical Sealant ā¢ FOD-5104 2006 Technical Service 1-800-992-1180 www.stifirestop.com Part # Description Packaging Size Color SNS105 Smoke & Acoustical Sealant Pail 5 gal.(1,155 cu. in, 19 L) White SNS105W Smoke & Acoustical Sealant Pail 5 gal. (1,155 cu. in, 19 L) White SNS120W Smoke & Acoustical Sealant Sausage 20 oz. (36 cu. in. 592 ml) White SNS129W Smoke & Acoustical Sealant Tube 29 oz. (52 cu. in. 858 ml) White SNS134W Smoke & Acoustical Sealant Sausage 34 oz. (61 cu. in. 1005 ml) White IMPORTANT NOTICE: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not guaranteed. LIMITED WARRANTY: STI warrants that its products will be free of defects for one year from the date of purchase. In the event a product does not conform to this warranty, the sole and exclusive remedy is, at STIās option, replacement of the product or refund of the purchase price. The warranty provided herein shall be void and of no effect in the event that the product is not installed in accordance with STIās published instructions, listed systems and applicable building and safety codes. THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS AND EXPRESSED OR IMPLIED WARRANTIES (including the implied warranties of merchantability or fitness for a particular use) AND UNDER NO CIRCUMSTANCES SHALL STI BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING, WITHOUT LIMITATION, ANY LOSS OF REVENUE, PROFIT OR USE. Prior to use, the user shall determine the suitability of the product for its intended use, and the user assumes all risks and liability for subsequent use. No person other than an officer of STI is authorized to bind STI to any other warranty for any product for which this warranty is issued. MADE IN THE USA ā COPYRIGHT Ā© 2016 SPECIFIED TECHNOLOGIES INC. MAINTENANCE TECHNICAL SERVICE PRECAUTIONARY INFORMATION AVAILABILITY No maintenance is normally required, however a periodic inspection of rated barriers is recommended to make sure that any new openings, modifications of previously installed seals, or areas exhibiting physical damage, have been properly sealed or repaired. Subsequent sealing or repairs should be accomplished using SpecSealĀ® Smoke 'N' Sound Sealant. RETROFIT: When adding or removing penetrants, care should be taken to minimize damage to the seal. Reseal using SpecSealĀ® Smoke āNā Sound. Specified Technologies Inc. provides toll free technical support to assist in product selection and installation information. UL Classified Systems are available at the Technical Library at www.stifirestop.com. SpecSealĀ® Smoke āNā Sound Sealant is non-flammable, non-toxic, non-irritating and environmentally safe. However, do not take internally. Refer to Material Safety Data Sheet for additional information. Wash areas of skin contact with soap and water. Avoid contact with eyes. SEALANT IS CONDUCTIVE UNTIL DRY. LIMITATIONS: SpecSealĀ® Smoke āNā Sound Sealant is water-based and cures through the evaporation of water. Low temperatures as well as high humidity may retard drying. Non-porous or impermeable backing materials, plates, or coatings may retard the drying process. This product has been designed to be safe with plastics and has been used extensively and successfully with a variety of different types of plastic pipes, tubes, and plastic cable insulations. Variations in these materials however, make it impossible to guarantee compatibility. STI strongly recommends that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this product. This product is recommended for use in sealing non-rated smoke barriers only and is not intended for use in fire-rated barriers. Consult the local Authority Having Jurisdiction for local code requirements regarding smoke rated barriers prior to installing this product. Consult Specified Technologies Inc. for recommendations concerning sealing applications in fire rated walls or floors. SpecSealĀ® Smoke āNā Sound Sealant is available from authorized distributors. Consult factory for the names and locations of the nearest sales representatives or distributors. Pipe Size Diameter of Opening (in.) 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10 12 14 26 Trade Pipe Size O.D. 0.5" 0.840 0.3 0.6 1.6 3.0 4.8 6.9 9.5 12.4 19.5 28.1 38.3 132.6 1" 1.315 0.1 0.4 1.4 2.8 4.6 6.7 9.3 12.2 19.3 27.9 38.1 132.4 1.5" 1.900 1.1 2.4 4.2 6.4 8.9 11.9 18.9 27.6 37.8 132.0 2" 2.375 0.7 2.0 3.8 6.0 8.5 11.5 18.5 27.2 37.4 131.6 2.5" 2.875 0.1 1.5 3.3 5.4 8.0 10.9 18.0 26.7 36.9 131.1 3" 3.500 0.7 2.5 4.7 7.2 10.2 17.2 25.9 36.1 130.3 3 .5" 4.000 1.8 3.9 6.5 9.4 16.5 25.1 35.3 129.6 4 " 4.500 0.8 3.0 5.6 8.5 15.6 24.2 34.4 128.7 6" 6.625 1.1 4.0 11.1 19.7 29.9 124.2 8" 8.625 4.9 13.6 23.8 118.0 1 0" 10.750 5.6 15.8 110.0 1 2" 12.750 6.6 100.8 24" 24.000 19.6 IMPORTANT NOTE: This table is for estimation purposes only. Consult UL Fire Resistance Directory or STI Product & Application Guide for specific installation requirements and limitations Metric Estimation Table available upon request. SEALANT REQUIREMENTS IN CUBIC INCHES PER 1/4 INCH OF INSTALLED DEPTH* *Different Sealant Depth? 1/2" Multiply by 2 5/8" Multiply by 2.5 1" Multiply by 4 1-1/4" Multiply by 5 Somerville, NJ 08876 USA ā¢ Phone: 800.992.1180 ā¢ Fax: 908.526.9623
|